WR Series Liquid Cooled Load Bank

  • Portable
  • Stationary / Permanent
  • Liquid Cooled


LIQUID COOLED · MODULAR 500 kW – 6.7 MW

WR Series Liquid Cooled Load Bank

Built for critical power. Driven by innovation. ASME-stamped, UL-listed, zero-leak design — engineered for CDU testing and modern liquid-cooled data center environments.

Universal Load Banks WR Series Liquid Cooled Load Bank

500 kW
– 6.7 MW
Modular Range
10–4500LPM Flow Range
ZeroLeak Design

Engineered for real thermal emulation, not just dissipation

Conventional load banks dissipate heat. ULB WR Series systems emulate actual server thermal behavior — enabling true CDU validation across the full operating envelope.

1

Modular design — available power from 500 kW to 6.7 MW
2

ASME Stamped, UL Listed — code-compliant with stainless-steel tanks and piping
3

Zero Leak Design with integral self-contained drip pan
4

Extended-range flow meters + proportional control valves for precise ΔT control
5

Intuitive HMI control — color touchscreen with Power Data, Safety, Data Logging
6

Outdoor-rated · network multiple load banks for fleet control

Real IT loads. Real thermal behavior.

Five capabilities that set the WR Series apart for cooling distribution unit (CDU) validation in modern liquid-cooled data centers.

Capability ULB WR Series RECOMMENDED Conventional Load Bank
Thermal Behavior Emulates actual server thermal behavior Dissipates heat only
Heat Distribution Multi-zone independent control Single-zone, fixed
Flow Range 10–4500 LPM (fixed + variable) Narrow flow window
ΔT Control Precise — proportional valves Coarse adjustment
Load Profiles 10 programmable · 30,000+ via LoadEZ Manual / preset only
Leak Containment Zero leak design + drip pan Standard fittings
Safety Auto-shutdown on leak / over-temp Manual shutdown common
Data Logging Real-time + exportable test reports Limited or none
Network Operation Multiple banks networked Standalone
Code Compliance ASME Stamped · UL / ETL / cUL Listed Varies by vendor

* LoadEZ™ software license sold separately.

Model-by-Model Spec Sheet

The WR Series comes in three standard models — WR750, WR1125, and MWR2250 — with rated power ranging from 750 kW to 2,250 kW. Larger 3 MW, 4.5 MW, and 6.7 MW configurations are also available on request — please contact sales for specifications.

Specification WR750 WR1125 MWR2250
Rated Power @ 480 V 750 kW 1,125 kW 2,250 kW
Rated Power @ 415 V 560 kW 840 kW 1,680 kW
Power Resolution Control 5 kW 5 kW 5 kW
UL Listing ETL / cUL / UL ETL / cUL / UL ETL / cUL / UL
System Code ASME ASME ASME
Operating Pressure 483 kPa (70 psig) 483 kPa (70 psig) 483 kPa (70 psig)
Max System Pressure 724 kPa (105 psig) 724 kPa (105 psig) 724 kPa (105 psig)
Min Flow Control 75 LPM (20 GPM) 113 LPM (30 GPM) 225 LPM (60 GPM)
Max Flow Control 1,500 LPM (396 GPM) 2,250 LPM (594 GPM) 4,500 LPM (1,190 GPM)
Total Tank Volume 250 L (66 gal) 375 L (99 gal) 749 L (198 gal)
Inlet/Outlet Connection 4″ ANSI Flange 6″ ANSI Flange 8″ ANSI Flange
Power Connection Cam Lock (4/phase) Bus Bar Bus Bar
Enclosure Rating NEMA 3R NEMA 3R NEMA 3R
Enclosure Style Portable Stationary Stationary-Containerized
Weight 1,102 kg (2,450 lb) 1,737 kg (3,860 lb) 4,950 kg (11,000 lb)

Where the WR Series delivers

CDU Testing

Cooling Distribution Unit Validation

True thermal emulation for liquid-cooled CDU performance testing across the full operating envelope.

Data Center

Liquid-Cooled Data Hall Commissioning

Multi-zone independent control simulates rack-, row-, and pod-level thermal load distribution.

AI Infrastructure

AI / GPU Workload Emulation

Programmable dynamic load profiles replicate AI-style transient thermal behavior.

R&D

Server & Cold Plate Testing

Precise ΔT control for cold plate and direct-to-chip cooling validation.

Industrial

Liquid-Cooled Power Electronics

Validation of inverters, drives, and high-density power conversion with realistic heat loads.

Commissioning

Extended Validation Programs

Built for safe, unattended operation during long-duration test campaigns.

A closer look at the WR Series

Purpose-built connections and an intuitive control interface — engineered for straightforward integration into modern liquid-cooled data centers and CDU test benches.

WR Series back view showing power connections and coolant ports
HARDWARE

Power & Coolant Connections

Color-coded quick-disconnect connectors, ANSI-flanged inlet/outlet ports, and a rugged NEMA 3R enclosure engineered for outdoor deployment.

WR Series HMI control panel with touchscreen, emergency stop, and phase controls
CONTROL INTERFACE

Intuitive HMI Panel

Color touchscreen HMI with Power Data, Safety, and Data Logging screens. E-Stop, per-phase controls, USB data export, and integrated PLC.

Take the details with you

Download the WR Series outline for a quick overview, or the full datasheet for model-by-model specifications.

PDF

Product Outline

One-page WR Series technical summary — models, key capabilities, applications.

PDF · 1 page

↓ Download

PDF

Full Datasheet

Complete 4-page WR Series datasheet with model-by-model specifications, controls, sensors, and certifications.

PDF · 4 pages

↓ Download

Questions about the WR Series

Common questions from CDU manufacturers, data center commissioning teams, and R&D engineers.

What’s the difference between a conventional load bank and the ULB WR Series for CDU testing?

Conventional load banks dissipate heat. The WR Series emulates actual server thermal behavior — making it suitable for true CDU performance validation, not just thermal stress testing.

What power range does the WR Series cover?

The modular range is 500 kW to 6.7 MW. Core models are WR750 (750 kW), WR1125 (1,125 kW), and MWR2250 (2,250 kW). Larger configurations of 3 MW, 4.5 MW, and 6.7 MW are also available.

What flow rates are supported?

Flow rates from 10 to 4,500 LPM are supported across the WR Series, with both fixed-flow and variable-flow testing modes.

How safe is the WR Series for unattended operation?

Designed for safe, unattended operation during extended validation programs. Safety features include leak detection with automatic shutdown, integral self-contained drip pan, over-temperature protection, low-flow and pressure monitoring, and pre-test diagnostics.

What certifications does the WR Series carry?

ASME Stamped, UL / ETL / cUL Listed. Manufactured in an ISO 9001:2015 certified facility.

Talk to a ULB Specialist

Get configuration sizing, technical consultation, or a quote for the WR Series. Our specialists respond within one business day.

P

Get in touch

Choose what works best — our existing contact form, a direct call, or a brochure download to share with your team.

Contact Sales
  • Technical Details
  • Physical Specifications & Inbuilt Safety
  • Features & Benefits
  • Options
  • Applications
  • Downloads

Technical Details

Power Factor

1.0

Duty Cycle

Continuous Duty

Cooling System

Liquid Cooled, Water Cooled

Physical Specifications & Inbuilt Safety